Show simple item record

dc.contributor.authorFarrow, L S
dc.contributor.authorSmith, T O
dc.contributor.authorAshcroft, G P
dc.contributor.authorMyint, P K
dc.date.accessioned2017-09-20T23:01:43Z
dc.date.available2017-09-20T23:01:43Z
dc.date.issued2016-12
dc.identifier.citationFarrow , L S , Smith , T O , Ashcroft , G P & Myint , P K 2016 , ' A systematic review of Tranexamic acid in hip fracture surgery ' , British Journal of Clinical Pharmacology , vol. 82 , no. 6 , pp. 1458-1470 . https://doi.org/10.1111/bcp.13079en
dc.identifier.issn0306-5251
dc.identifier.otherPURE: 69745374
dc.identifier.otherPURE UUID: c8135381-3f2e-4eaf-b1da-4291e8af3e4b
dc.identifier.otherScopus: 84988311543
dc.identifier.otherORCID: /0000-0002-5374-624X/work/46423827
dc.identifier.urihttp://hdl.handle.net/2164/9326
dc.descriptionCOMPETING INTERESTS & FINANCIAL SUPPORT “All authors have completed the Unified Competing Interest form and declare: no support from any organisation for the submitted work; no financial relationships with any organisations that might have an interest in the submitted work in the previous 3 years; no other relationships or activities that could appear to have influenced the submitted work”en
dc.format.extent13
dc.language.isoeng
dc.relation.ispartofBritish Journal of Clinical Pharmacologyen
dc.rightsThis is the peer reviewed version of the following article: Farrow, L. S., Smith, T. O., Ashcroft, G. P., and Myint, P. K. (2016) A systematic review of tranexamic acid in hip fracture surgery. Br J Clin Pharmacol, 82: 1458–1470., which has been published in final form at DOI: 10.1111/bcp.13079. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.en
dc.subjectbleedingen
dc.subjectfemoral neck fractureen
dc.subjecthip fractureen
dc.subjectmeta-analysisen
dc.subjectorthopaedicsen
dc.subjectsurgeryen
dc.subjectsystematic reviewen
dc.subjecttranexamic aciden
dc.subjecttransfusionen
dc.subjecttraumaen
dc.subjectR Medicineen
dc.subject.lccRen
dc.titleA systematic review of Tranexamic acid in hip fracture surgeryen
dc.typeJournal articleen
dc.contributor.institutionUniversity of Aberdeen.Applied Medicineen
dc.contributor.institutionUniversity of Aberdeen.Other Applied Health Sciencesen
dc.contributor.institutionUniversity of Aberdeen.Institute of Applied Health Sciencesen
dc.contributor.institutionUniversity of Aberdeen.Clinical Medicineen
dc.description.statusPeer revieweden
dc.description.versionPostprinten
dc.description.versionPostprinten
dc.description.versionPostprinten
dc.description.versionPostprinten
dc.identifier.doihttps://doi.org/10.1111/bcp.13079
dc.date.embargoedUntil2017-09-20


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record