Does mixing inhaler devices lead to unchecked inhaler technique errors in patients with COPD? : Findings from the cross-sectional observational MISMATCH study

dc.contributor.authorDijk, Lars
dc.contributor.authorKerkhof, Marjan
dc.contributor.authorDriessen, Merijn
dc.contributor.authorGerritsma, Yoran H.
dc.contributor.authorBosnic-Anticevich, Sinthia
dc.contributor.authorCorreia-De-Sousa, Jaime
dc.contributor.authorDekhuijzen, P. N.Richard
dc.contributor.authorLeving, Marika
dc.contributor.authorPrice, David B.
dc.contributor.authorTsiligianni, Ioanna
dc.contributor.authorUsmani, Omar
dc.contributor.authorKerstjens, Huib A.M.
dc.contributor.authorKocks, Janwillem W.H.
dc.contributor.institutionUniversity of Aberdeen.Institute of Applied Health Sciencesen
dc.contributor.institutionUniversity of Aberdeen.Other Applied Health Sciencesen
dc.date.accessioned2024-02-22T12:22:01Z
dc.date.available2024-02-22T12:22:01Z
dc.date.issued2023-12-22
dc.descriptionFunding Information: The members of the MISMATCH study group would like to acknowledge Titia Klemmeijer (founder of the IMIS foundation; 'Inhalatie Medicatie Instruction School') for her assistance in formulating the list of additional errors, and Chantal Arling, Thomas le Rutte & Landy Torre for their time and efforts to perform the reassessments of the video recordings. Finally, they would like to thank the participants who generously gave their time to participate in the PIFotal study and provided informed consent to use their video/data for future research. This work was supported by Chiesi Pharmaceuticals. The PIFotal study was cofunded by Boehringer Ingelheim.en
dc.description.statusPeer revieweden
dc.format.extent11
dc.format.extent807242
dc.identifier284437077
dc.identifierbfa36f67-6a37-4473-8ee1-10d76b440435
dc.identifier85181177134
dc.identifier38135462
dc.identifier.citationDijk, L, Kerkhof, M, Driessen, M, Gerritsma, Y H, Bosnic-Anticevich, S, Correia-De-Sousa, J, Dekhuijzen, P N R, Leving, M, Price, D B, Tsiligianni, I, Usmani, O, Kerstjens, H A M & Kocks, J W H 2023, 'Does mixing inhaler devices lead to unchecked inhaler technique errors in patients with COPD? Findings from the cross-sectional observational MISMATCH study', BMJ Open Respiratory Research, vol. 10, no. 1, e001821. https://doi.org/10.1136/bmjresp-2023-001821en
dc.identifier.doi10.1136/bmjresp-2023-001821
dc.identifier.iss1en
dc.identifier.issn2052-4439
dc.identifier.urihttps://hdl.handle.net/2164/22824
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85181177134&partnerID=8YFLogxKen
dc.identifier.vol10en
dc.language.isoeng
dc.relation.ispartofBMJ Open Respiratory Researchen
dc.subjectRC Internal medicineen
dc.subjectPulmonary and Respiratory Medicineen
dc.subject.lccRCen
dc.titleDoes mixing inhaler devices lead to unchecked inhaler technique errors in patients with COPD? : Findings from the cross-sectional observational MISMATCH studyen
dc.typeJournal articleen

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Dijk_etal_BMJO_Does_Mixing_Inhaler_VOR.pdf
Size:
788.32 KB
Format:
Adobe Portable Document Format

Collections