Changes in hot spring temperature and hydrogeology of the Alpine fault hanging wall, New Zealand, induced by distal South Island earthquakes

dc.contributor.authorCox, S. C.
dc.contributor.authorMenzies, C. D.
dc.contributor.authorSutherland, R.
dc.contributor.authorDenys, P. H.
dc.contributor.authorChamberlain, C.
dc.contributor.authorTeagle, D. A. H.
dc.contributor.institutionUniversity of Aberdeen.Geology and Geophysicsen
dc.date.accessioned2018-12-04T14:40:06Z
dc.date.available2018-12-04T14:40:06Z
dc.date.issued2015-02
dc.descriptionSamples from the Westland National Park were collected under Department of Conservation permit WC‐22994‐GEO. This project was funded under GNS Science's ‘Impacts of Global Plate Tectonics in and around New Zealand Programme’ (PGST Contract C05X0203). Geochemical analyses were funded by a Natural Environmental Research Council‐CASE PhD studentship award NE/G524160/1 to CDM (GNS Science CASE Partner) and NERC grants NE/H012842/1, NE/J024449/1 and IP‐1187‐0510 to DAHT. We acknowledge the New Zealand GeoNet project and its sponsors EQC, GNS Science and LINZ, as well as the late John Beavan, for providing data used in this study. We wish to thank our colleagues John Townend, Jim Cousins, John Haines, Carolin Boese, Rachael James, Dave Craw, Delia Strong and Agnes Reyes for discussions and helpful comments, although not necessarily implying they agree with all of our interpretations and conclusions.en
dc.description.statusPeer revieweden
dc.format.extent24
dc.format.extent4061996
dc.identifier139892430
dc.identifier57909471-79c3-492c-80be-faa7c23f7543
dc.identifier84923130393
dc.identifier.citationCox, S C, Menzies, C D, Sutherland, R, Denys, P H, Chamberlain, C & Teagle, D A H 2015, 'Changes in hot spring temperature and hydrogeology of the Alpine fault hanging wall, New Zealand, induced by distal South Island earthquakes', GeoFluids, vol. 15, no. 1-2, pp. 216-239. https://doi.org/10.1111/gfl.12093en
dc.identifier.doi10.1111/gfl.12093
dc.identifier.iss1en
dc.identifier.issn1468-8115
dc.identifier.otherORCID: /0000-0003-3268-0007/work/54384831
dc.identifier.urihttp://hdl.handle.net/2164/11561
dc.identifier.vol15en
dc.language.isoeng
dc.relation.ispartofGeoFluidsen
dc.subjectCopland hot springen
dc.subjectearthquakeen
dc.subjectfluid flowen
dc.subjectorogenic geothermal systemsen
dc.subjectpermeability changeen
dc.subjectWelcome Flaten
dc.subjectQE Geologyen
dc.subjectNatural Environment Research Council (NERC)en
dc.subjectNE/G524160/1en
dc.subjectNE/H012842/1en
dc.subjectNE/J024449/1en
dc.subjectIP‐1187‐0510en
dc.subject.lccQEen
dc.titleChanges in hot spring temperature and hydrogeology of the Alpine fault hanging wall, New Zealand, induced by distal South Island earthquakesen
dc.typeJournal articleen