University of Aberdeen logo

AURA - Aberdeen University Research Archive

 

Mechanical properties of cancellous bone from the acetabulum in relation to acetabular shell fixation and compared with the corresponding femoral head

dc.contributor.authorVan Ladesteijn, Rianne
dc.contributor.authorLeslie, Holly
dc.contributor.authorManning, William A.
dc.contributor.authorHolland, James P.
dc.contributor.authorDeeham, David J.
dc.contributor.authorPandorf, Thomas
dc.contributor.authorAspden, Richard M.
dc.contributor.institutionUniversity of Aberdeen.Medical Sciencesen
dc.contributor.institutionUniversity of Aberdeen.Applied Medicineen
dc.contributor.institutionUniversity of Aberdeen.Aberdeen Centre for Research Excellence in Musculoskeletal Health: Collaborate. Innovate. Translate.en
dc.date.accessioned2019-02-01T00:05:19Z
dc.date.available2019-02-01T00:05:19Z
dc.date.embargoedUntil2019-02-01
dc.date.issued2018-03
dc.descriptionAcknowledgments We thank Phil Jackson for help sourcing donated cadavers and transportation of samples and Dr. F.R. Saunders for help with core preparation and advice. Funding This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.en
dc.description.statusPeer revieweden
dc.format.extent7
dc.format.extent4667801
dc.identifier115714077
dc.identifierf45a6d03-873e-450f-bc4a-be2da7233d84
dc.identifier85041131431
dc.identifier.citationVan Ladesteijn, R, Leslie, H, Manning, W A, Holland, J P, Deeham, D J, Pandorf, T & Aspden, R M 2018, 'Mechanical properties of cancellous bone from the acetabulum in relation to acetabular shell fixation and compared with the corresponding femoral head', Medical Engineering & Physics, vol. 53, pp. 75-81. https://doi.org/10.1016/j.medengphy.2018.01.005en
dc.identifier.doi10.1016/j.medengphy.2018.01.005
dc.identifier.issn1350-4533
dc.identifier.urihttp://hdl.handle.net/2164/11850
dc.language.isoeng
dc.relation.ispartofMedical Engineering & Physicsen
dc.subjectCementless fixationen
dc.subjectAcetabulumen
dc.subjectBoneen
dc.subjectMechanical propertiesen
dc.subjectMechanical testingen
dc.subjectViscoelasticen
dc.subjectR Medicine (General)en
dc.subject.lccR1en
dc.titleMechanical properties of cancellous bone from the acetabulum in relation to acetabular shell fixation and compared with the corresponding femoral headen
dc.typeJournal articleen

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
MEP_acetabular_bone_accepted_version.pdf
Size:
4.45 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
8.31 KB
Format:
Plain Text
Description: