University of Aberdeen logo

AURA - Aberdeen University Research Archive

 

A Practical Sensor-to-Segment Calibration Method for Upper Limb Inertial Motion Capture in a Clinical Setting

dc.contributor.authorMcInnes, Mhairi
dc.contributor.authorBlana, Dimitra
dc.contributor.authorStarkey, Andrew
dc.contributor.authorChadwick, Edward
dc.contributor.institutionUniversity of Aberdeen.Engineeringen
dc.contributor.institutionUniversity of Aberdeen.Other Applied Health Sciencesen
dc.contributor.institutionUniversity of Aberdeen.Aberdeen Centre for Health Data Scienceen
dc.contributor.institutionUniversity of Aberdeen.Engineeringen
dc.contributor.institutionUniversity of Aberdeen.Aberdeen Biomedical Imaging Centreen
dc.date.accessioned2025-05-15T09:39:01Z
dc.date.available2025-05-15T09:39:01Z
dc.date.issued2025
dc.descriptionFor the purpose of open access, the author has applied a Creative Commons Attribution (CC BY) licence to any Author Accepted Manuscript version arising from this submission.en
dc.description.statusPeer revieweden
dc.format.extent11
dc.format.extent1771420
dc.identifier303923853
dc.identifierccdc1839-05f4-40bd-a4ec-08793799afe8
dc.identifier105004395031
dc.identifier40657525
dc.identifier.citationMcInnes, M, Blana, D, Starkey, A & Chadwick, E 2025, 'A Practical Sensor-to-Segment Calibration Method for Upper Limb Inertial Motion Capture in a Clinical Setting', IEEE Journal of Translational Engineering in Health and Medicine, vol. 13, pp. 216-226. https://doi.org/10.1109/JTEHM.2025.3565986en
dc.identifier.doi10.1109/JTEHM.2025.3565986
dc.identifier.issn2168-2372
dc.identifier.otherRIS: urn:5907314C7B46EFC3990E1521DBFDF853
dc.identifier.otherORCID: /0000-0003-0877-5110/work/184349996
dc.identifier.otherORCID: /0000-0003-0488-6120/work/184350401
dc.identifier.urihttps://hdl.handle.net/2164/25462
dc.identifier.vol13en
dc.language.isoeng
dc.relation.ispartofIEEE Journal of Translational Engineering in Health and Medicineen
dc.subjectSubstantive connection via an eligible employment contracten
dc.subjectSDG 3 - Good Health and Well-beingen
dc.subjectClinical motion analysisen
dc.subjectIMUen
dc.subjectjoint axes estimationen
dc.subjectwearable sensorsen
dc.subjectR Medicine (General)en
dc.subjectSupplementary Dataen
dc.subjectDASen
dc.subjectSupplementary Informationen
dc.subject.lccR1en
dc.titleA Practical Sensor-to-Segment Calibration Method for Upper Limb Inertial Motion Capture in a Clinical Settingen
dc.typeJournal articleen

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
McInnes_IEEEJoT_A_Practical_Sensor_VOR.pdf
Size:
1.69 MB
Format:
Adobe Portable Document Format

Collections