A flexible 8.5 MHz litz wire receive array for field-cycling imaging
| dc.contributor.author | Stormont, Robert Steven | |
| dc.contributor.author | Davies, Gareth | |
| dc.contributor.author | Ross, James | |
| dc.contributor.author | Lurie, David | |
| dc.contributor.author | Broche, Lionel | |
| dc.contributor.institution | University of Aberdeen.Medicine, Medical Sciences & Nutrition | en |
| dc.contributor.institution | University of Aberdeen.Institute of Medical Sciences | en |
| dc.contributor.institution | University of Aberdeen.Aberdeen Biomedical Imaging Centre | en |
| dc.contributor.institution | University of Aberdeen.Applied Medicine | en |
| dc.contributor.institution | University of Aberdeen.Medical Sciences | en |
| dc.contributor.institution | University of Aberdeen.Aberdeen Centre for Arthritis and Musculoskeletal Health (ACAMH) | en |
| dc.date.accessioned | 2023-07-20T15:03:01Z | |
| dc.date.available | 2023-07-20T15:03:01Z | |
| dc.date.issued | 2023-03-07 | |
| dc.description | Open Access via the IOP Agreement | en |
| dc.description.status | Peer reviewed | en |
| dc.format.extent | 19 | |
| dc.format.extent | 2202366 | |
| dc.identifier | 227695749 | |
| dc.identifier | dd76247d-de6c-4057-9700-9e790d7d6b9b | |
| dc.identifier | 36750000 | |
| dc.identifier | 85148964599 | |
| dc.identifier.citation | Stormont, R S, Davies, G, Ross, J, Lurie, D & Broche, L 2023, 'A flexible 8.5 MHz litz wire receive array for field-cycling imaging', Physics in Medicine and Biology, vol. 68, no. 5, 055016. https://doi.org/10.1088/1361-6560/acb9d0 | en |
| dc.identifier.doi | 10.1088/1361-6560/acb9d0 | |
| dc.identifier.iss | 5 | en |
| dc.identifier.issn | 0031-9155 | |
| dc.identifier.other | ORCID: /0000-0002-6009-3152/work/130881562 | |
| dc.identifier.other | ORCID: /0000-0002-8452-9838/work/130882063 | |
| dc.identifier.other | ORCID: /0000-0001-7984-6452/work/130882227 | |
| dc.identifier.other | ORCID: /0009-0004-0622-4459/work/130882452 | |
| dc.identifier.uri | https://hdl.handle.net/2164/21272 | |
| dc.identifier.vol | 68 | en |
| dc.language.iso | eng | |
| dc.relation.ispartof | Physics in Medicine and Biology | en |
| dc.subject | Substantive connection via an eligible employment contract | en |
| dc.subject | RF coil | en |
| dc.subject | Array | en |
| dc.subject | Low-field | en |
| dc.subject | Litz wire | en |
| dc.subject | Preamplifier | en |
| dc.subject | Noise figure | en |
| dc.subject | Signal-To_Noise | en |
| dc.subject | Flexible | en |
| dc.subject | R Medicine | en |
| dc.subject.lcc | R | en |
| dc.title | A flexible 8.5 MHz litz wire receive array for field-cycling imaging | en |
| dc.type | Journal article | en |
Files
Original bundle
1 - 1 of 1
- Name:
- Stormont_etal_PiMaB_A_Flexible_8.5_VOR.pdf
- Size:
- 2.1 MB
- Format:
- Adobe Portable Document Format