Standardization of preclinical PET/CT imaging to improve quantitative accuracy, precision and reproducibility : a multi-center study
| dc.contributor.author | McDougald, Wendy | |
| dc.contributor.author | Vanhove, Christian | |
| dc.contributor.author | Lehnert, Adrienne | |
| dc.contributor.author | Lewellen, Barbara | |
| dc.contributor.author | Wright, John | |
| dc.contributor.author | Mingarelli, Marco | |
| dc.contributor.author | Corral, Carlos Alcaide | |
| dc.contributor.author | Schneider, Jürgen | |
| dc.contributor.author | Plein, Sven | |
| dc.contributor.author | Newby, David | |
| dc.contributor.author | Welch, Andy | |
| dc.contributor.author | Miyaoka, Robert | |
| dc.contributor.author | Vandenberghe, Stefaan | |
| dc.contributor.author | Tavares, Adriana Alexandre S. | |
| dc.contributor.institution | University of Aberdeen.Riedel's Research Group | en |
| dc.contributor.institution | University of Aberdeen.Energy | en |
| dc.contributor.institution | University of Aberdeen.Medical Education | en |
| dc.contributor.institution | University of Aberdeen.Aberdeen Biomedical Imaging Centre | en |
| dc.date.accessioned | 2020-04-09T12:00:01Z | |
| dc.date.available | 2020-04-09T12:00:01Z | |
| dc.date.issued | 2020-03-01 | |
| dc.description | We thank the National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs) for funding this work (Studentship grant NC/P00170X/1) to WM. AT is funded by the British Heart Foundation (RG/16/10/32375). The British Heart Foundation is greatly acknowledge for providing funding towards establishment of the Edinburgh Preclinical PET/CT laboratory (RE/13/3/30183). The authors would like to thank the radiochemistry teams at Edinburgh Imaging, Queen's Medical Research Institute (QMRI), the University of Aberdeen and Ghent University for their support in supplying the radiotracers used during the site visits. | en |
| dc.description.status | Peer reviewed | en |
| dc.format.extent | 8 | |
| dc.format.extent | 1151192 | |
| dc.identifier | 146959999 | |
| dc.identifier | 6aa0bbe5-b197-4651-baea-d956363795f5 | |
| dc.identifier | 000518436700031 | |
| dc.identifier | 85081136965 | |
| dc.identifier.citation | McDougald, W, Vanhove, C, Lehnert, A, Lewellen, B, Wright, J, Mingarelli, M, Corral, C A, Schneider, J, Plein, S, Newby, D, Welch, A, Miyaoka, R, Vandenberghe, S & Tavares, A A S 2020, 'Standardization of preclinical PET/CT imaging to improve quantitative accuracy, precision and reproducibility : a multi-center study', Journal of Nuclear Medicine, vol. 61, no. 3, pp. 461-468. https://doi.org/10.2967/jnumed.119.231308 | en |
| dc.identifier.doi | 10.2967/jnumed.119.231308 | |
| dc.identifier.iss | 3 | en |
| dc.identifier.issn | 0161-5505 | |
| dc.identifier.other | SCOPUS: 85081136965 | |
| dc.identifier.uri | https://hdl.handle.net/2164/14003 | |
| dc.identifier.url | http://www.scopus.com/inward/record.url?scp=85081136965&partnerID=8YFLogxK | en |
| dc.identifier.vol | 61 | en |
| dc.language.iso | eng | |
| dc.relation.ispartof | Journal of Nuclear Medicine | en |
| dc.subject | Preclinical PET/CT | en |
| dc.subject | Standardization | en |
| dc.subject | Hounsfield Units | en |
| dc.subject | Absorbed dose | en |
| dc.subject | Recovery coefficient | en |
| dc.subject | absorbed dose | en |
| dc.subject | recovery coefficient | en |
| dc.subject | standardization | en |
| dc.subject | Hounsfield units | en |
| dc.subject | preclinical PET/CT | en |
| dc.subject | TOMOGRAPHY | en |
| dc.subject | MICRO-CT | en |
| dc.subject | R Medicine (General) | en |
| dc.subject | Radiology Nuclear Medicine and imaging | en |
| dc.subject | National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3R's) | en |
| dc.subject | NC/P00170X/1 | en |
| dc.subject | British Heart Foundation | en |
| dc.subject | RG/16/10/32375 | en |
| dc.subject | RE/13/3/30183 | en |
| dc.subject.lcc | R1 | en |
| dc.title | Standardization of preclinical PET/CT imaging to improve quantitative accuracy, precision and reproducibility : a multi-center study | en |
| dc.type | Journal article | en |
Files
Original bundle
1 - 1 of 1
