Correlations of low-field NMR and variable-field NMR parameters with osteoarthritis in human articular cartilage under load
| dc.contributor.author | Rössler, Erik | |
| dc.contributor.author | Mattea, Carlos | |
| dc.contributor.author | Saarakkala, Simo | |
| dc.contributor.author | Lehenkari, Petri | |
| dc.contributor.author | Finnilä, Mikko | |
| dc.contributor.author | Rieppo, Lassi | |
| dc.contributor.author | Karhula, Sakari | |
| dc.contributor.author | Nieminen, Miika T. | |
| dc.contributor.author | Stapf, Siegfried | |
| dc.contributor.institution | University of Aberdeen.Applied Medicine | en | 
| dc.date.accessioned | 2019-12-20T12:05:01Z | |
| dc.date.available | 2019-12-20T12:05:01Z | |
| dc.date.embargoedUntil | 2017-07-24 | |
| dc.date.issued | 2017-08 | |
| dc.description | Part of this work was supported by the EU Horizon 2020 collaborative project IDentIFY (project number 668119). ER gratefully acknowledges Carl Zeiss Stiftung for the scholarship to pursue his PhD research. MTN is indebted to Jane and Aatos Erkko Foundation, Finland for financial support. SS wishes to thank Professor Yang Xia for continuous valuable discussions. The assistance of Maarit Valkealahti in acquiring osteochondral specimens is gratefully acknowledged. | en | 
| dc.description.status | Peer reviewed | en | 
| dc.format.extent | 557000 | |
| dc.identifier | 147851894 | |
| dc.identifier | d7b4f4b6-558c-49b6-b0a4-6985f4893e04 | |
| dc.identifier | 85019923777 | |
| dc.identifier | 28543921 | |
| dc.identifier.citation | Rössler, E, Mattea, C, Saarakkala, S, Lehenkari, P, Finnilä, M, Rieppo, L, Karhula, S, Nieminen, M T & Stapf, S 2017, 'Correlations of low-field NMR and variable-field NMR parameters with osteoarthritis in human articular cartilage under load', NMR in Biomedicine, vol. 30, no. 8, e3738. https://doi.org/10.1002/nbm.3738 | en | 
| dc.identifier.doi | 10.1002/nbm.3738 | |
| dc.identifier.iss | 8 | en | 
| dc.identifier.issn | 0952-3480 | |
| dc.identifier.uri | https://hdl.handle.net/2164/13412 | |
| dc.identifier.url | http://www.scopus.com/inward/record.url?scp=85019923777&partnerID=8YFLogxK | en | 
| dc.identifier.vol | 30 | en | 
| dc.language.iso | eng | |
| dc.relation.ispartof | NMR in Biomedicine | en | 
| dc.subject | SDG 3 - Good Health and Well-being | en | 
| dc.subject | cartilage | en | 
| dc.subject | low-field NMR | en | 
| dc.subject | mechanical load | en | 
| dc.subject | osteoarthritis | en | 
| dc.subject | quadrupolar dips | en | 
| dc.subject | relaxometry | en | 
| dc.subject | R Medicine | en | 
| dc.subject | QC Physics | en | 
| dc.subject | Molecular Medicine | en | 
| dc.subject | Radiology Nuclear Medicine and imaging | en | 
| dc.subject | Spectroscopy | en | 
| dc.subject | European Commission | en | 
| dc.subject | 668119 | en | 
| dc.subject.lcc | R | en | 
| dc.subject.lcc | QC | en | 
| dc.title | Correlations of low-field NMR and variable-field NMR parameters with osteoarthritis in human articular cartilage under load | en | 
| dc.type | Journal article | en | 
Files
Original bundle
1 - 1 of 1
- Name:
- R_ssler_et_al_2017_NMR_in_Biomedicine_VOR.pdf
- Size:
- 543.95 KB
- Format:
- Adobe Portable Document Format
